The CA horizontal stainless steel single-stage centrifugal pump features axial suction and radial exhaust. Its counter-axial design allows for easy removal of the motor and impeller without disassembling the pump casing and piping, facilitating maintenance.
The CA horizontal Stainless Centrifugal Pump is precision-cold-stamped from stainless steel sheet.
Features
- Utilizes new hydraulic bulging technology for a secure structure.
- Voltage flow path design for high efficiency.
- Pump body, pump cover, impeller, and other flow-through components are made of SUS304.
- Elegant square motor design.
- Lightweight structure, mild corrosion resistance, and durability.
- Mechanical shaft seal for safety and leak resistance.
- Connection: Flange connection, installation dimensions comply with GB5662 & EN733 standards.
application

The CA Stainless Centrifugal Pump is a versatile product from Sihong, suitable for transporting a variety of media, including water and industrial liquids, across a wide range of flow rates and pressures.
Typical applications include:
- Water supply: water plant transportation, zoned water supply, and main pressure boosting
- Industrial pressure boosting: process water systems, cleaning systems, brewing and food industry systems
- Industrial liquid transportation: boiler feed water, cooling and air conditioning systems, condensate systems, and weak acid and weak base transportation
- Water treatment: raw water transportation, swimming pool systems
- Agricultural irrigation, healthcare, petrochemicals, aquaculture, and more.
Conditions of Use
- Clean, non-flammable, non-explosive liquids free of solid particles and fibers
- Liquids with a temperature between -20°C and +104°C
- Ambient temperature up to +50°C
- Installation altitude up to 1000 meters
- Maximum operating pressure 10 bar
motor
- Equipped with a fully enclosed, air-cooled, 2-pole or 4-pole extended-shaft motor
- Protection Rating: IP55
- Insulation Class: F
- Power Supply (±10%): 1 x 220V/50Hz, 3 x 220V/380V/50Hz. Single-phase motors are available from 0.37 to 2.2kW. Includes a built-in thermal protector.
NPSH

It is recommended to calculate the inlet pressure "H" in the following situations:
- High liquid temperature
- Flow rate significantly exceeding the rated flow rate
- Pumping from a low location
- Pumping from a long pipeline
Poor inlet conditions: To avoid cavitation, a minimum pressure must be maintained on the pump's inlet side.
The maximum suction head "H" in meters of head can be calculated using the following formula:
H = Pb x 10.2 - NPSH - Hf - Hv - HS
Pb = atmospheric pressure, in bar (atmospheric pressure is considered 1 bar). In closed systems, Pb represents the system pressure (in bar).
NPSH = Net Positive Suction Head, in meters (can be read from the pump's NPSH performance curve in the catalog).
Hf = Friction loss in the suction piping (in meters).
Hv = Vapor pressure (in meters), can be read from a vapor pressure gauge.
Hs = Safety margin, with a minimum of 0.5 meters.
If the calculated H value is positive, the pump can suction a head of "H" meters on the suction side. If it is negative, the inlet must have a head of at least positive "H" meters to prevent cavitation in the pump.
installation
- When installing piping, ensure that the pump casing is not subjected to external forces from the piping.
- The Stainless Centrifugal Pump must not be installed with the motor below it.
- The pump should be installed horizontally on a flat, solid foundation, with the pump's suction inlet facing horizontally and the discharge outlet facing vertically.
- To facilitate inspection and maintenance and allow for air flow, allow at least 0.3m of clearance behind the motor.
- The pump's inlet pipe diameter must not be smaller than the specified size.
- The pump should be installed in a well-ventilated and frost-proof area.
- If the pump is installed outdoors, it must be properly covered to prevent water from entering the electrical components.
- The electrical wiring must protect the pump from damage caused by phase loss, leakage, voltage fluctuations, and overload.
- To ensure optimal operation and minimize noise and vibration, vibration damping measures may be necessary in some applications.
Dissection drawing

| No. | Name | No. | Name |
|---|---|---|---|
| 1 | Hexagonal Nut | 2 | Spring Washer |
| 3 | Washer | 4 | Pump housring component |
| 5 | O-Ring | 6 | Plug |
| 7 | Hexagonal Nut | 8 | Spring Washer |
| 9 | Washer | 10 | Flat Key |
| 11 | Impeller | 12 | Mechanical seal |
| 13 | O-Ring | 14 | Stainless Centrifugal Pump Cover |
| 15 | Motor | 16 | Hexagonal Bolt |
| 17 | Hexagonal Bolt | 18 | Washer |
| 19 | Base |