The subway pump for mtr sewage lift is a key facility in the subway transportation system. Its main function is to collect the sewage generated in the subway station and effectively lift it to an appropriate height through a lifting pump so that it can enter the sewage treatment system, ensuring that the subway Cleanliness and sanitation of the station environment.

Performance parameters

Ambient temperature: 0°C~40C
Sewage temperature: 0C~40 (can transport 60C liquid in a short time)
Maximum density of sewage: 1600kg/m³
Sewage PH value: 6~9
Flow range:0~50m³/h
Lift range: 0~50m
Single pump power range: 4~15KW
Control cabinet protection level: IP55
Maximum number of starts of water pump: 20 times/hour
Features

● Sealed, no smell, environmentally friendly and hygienic
● Compact structure, saving space
● Quick and easy installation
● The water collection tank interface and the pipeline are flexibly connected with rubber hoses, which can reduce noise and vibration to a limited extent.
● Soft seal gate valves are installed at the inlet and outlet of the subway pump to facilitate maintenance.
● By installing a manual diaphragm pump (optional), the sewage in the water collecting tank can be manually drained when the electric pump fails or is repaired.
● Dual pump configuration, mutual backup; if the sewage inflow exceeds the flow range of a single pump, the other one can be put into operation as a supplementary pump.
● The liquid level sensor adopts air pressure + alarm float, ultrasonic liquid level meter + alarm float or float control methods.
● The subway pump adopts an innovatively designed dry spiral cutting pump, which greatly improves the passage capacity of dirt, is non-blocking and is easy to maintain.
● The water pump can be selected as a horizontal pump or a vertical pump according to needs.
● You can also choose a cyclone pump, which is suitable for situations where there are too many solid objects.
● Use a motor that can withstand frequent starting current shocks, with a protection level of IP68, and can still operate normally even when completely submerged.
● Uniquely designed cooling structure ensures efficient heat dissipation of the motor.
● Automatic flushing function to prevent sedimentation and blockage, water outlet diameter DN80 (variable diameter).
● The standard cable length between the controller and the water pump/control line is 10 meters (the cable length can be customized).

Material details

Water collection tank: polyethylene/stainless steel
Motor housing: cast iron HT250
Ambient temperature: 0°C~40C
Impeller: ductile cast iron QT450°C~40C
Drive shaft: 2Cr13°C~40C
Cooling jacket: stainless steel°C~40C
Mechanical seal: silicon carbide°C~40C
Pump housing: HT250°C~40C
Seal: NB°C~40C
Technical Parameters
|
Model |
Power (KW) |
Voltage (V) |
Current (A) |
Outlet |
Flow (m³/h) |
10 |
15 |
20 |
25 |
30 |
35 |
40 |
45 |
50 |
|
500L400D/H |
4 |
380 |
8.8 |
DN80 |
Head(m) |
25 |
23 |
21 |
19 |
17 |
15 |
13 |
11 |
9 |
|
500L550D/H |
5.5 |
11.7 |
33 |
31 |
29 |
27 |
25 |
23 |
21 |
17 |
14 |
|||
|
500L750D/H |
7.5 |
15.7 |
41 |
40 |
39 |
37 |
35 |
33 |
26 |
26 |
22 |
|||
|
500L1100D/H |
11 |
22.8 |
49 |
48 |
47 |
46 |
44 |
42 |
40 |
38 |
36 |
|||
|
500L1500D/H |
15 |
30.8 |
54 |
53 |
52 |
51 |
50 |
49 |
46 |
44 |
42 |
|||
|
1000L400D/H |
4 |
380 |
8.8 |
DN80 |
Head(m) |
25 |
23 |
21 |
19 |
17 |
15 |
13 |
11 |
9 |
|
1000L550D/H |
5.5 |
11.7 |
33 |
31 |
29 |
27 |
25 |
23 |
21 |
17 |
14 |
|||
|
1000L750D/H |
7.5 |
15.7 |
41 |
40 |
39 |
37 |
35 |
33 |
26 |
26 |
22 |
|||
|
1000L1100D/H |
11 |
22.8 |
49 |
48 |
47 |
46 |
44 |
42 |
40 |
38 |
36 |
|||
|
1000L1500D/H |
15 |
30.8 |
54 |
53 |
52 |
51 |
50 |
49 |
46 |
44 |
42 |
Installation diagram