The Sewer Lift Pump Residential is a complete wastewater collection and lifting system for basement bathrooms, villas, residential renovations, small commercial premises, and other areas below the main sewer line. The MSLR 150 series features an approximately 150 L corrosion-resistant PE tank with multiple inlet options for flexible installation. Depending on project requirements, it can be equipped with a vortex or semi-open impeller pump and an HT250 cast-iron or SUS304 stainless-steel pump body. MISLIER recommends suitable configurations based on wastewater type, flow rate, lift height, discharge distance, and pipe layout.
Advantages
Approximately 150 L Collection Capacity:The tank provides temporary storage for wastewater from several sanitary fixtures, making the system suitable for residential and light-commercial projects where multiple fixtures may discharge within a short period.
Flexible Multi-Inlet Design:Horizontal and vertical inlet positions support connections from toilets, washbasins, showers, and other drainage fixtures. Unused openings must be properly sealed to maintain tank airtightness.
Up to 60 mm Solids Passage:The non-clogging vortex hydraulic design provides a solids passage of up to 60 mm for domestic sewage containing mixed solids or short fibrous matter. Wet wipes, sanitary products, cloth, plastic bags, and other non-dispersible waste must not enter the unit.
Dual-Level Control:Air-pressure and float-switch level controls allow the pump to start and stop automatically as the wastewater level changes, while providing an additional layer of operating protection.
Protection for Demanding Conditions:The submersible pump is rated IP68, excluding the external control box. Motor overload and overheating protection help reduce the risk of damage under abnormal operating conditions.
DN80 Check Valve Included:The standard DN80 check valve helps prevent wastewater in the discharge pipe from flowing back into the collection tank after the pump stops.
Optional Dual-Pump Configuration:For projects where drainage continuity matters, two pumps can alternate operation to balance running hours. One pump may provide standby capacity while the other is inspected, subject to the actual flow, head, and system design.
MISLIER Selection and Installation Support:Distributors and contractors can send us the fixture list, required flow, total head, pipe route, and power supply. We use this information to recommend a practical configuration and reduce avoidable selection errors.
Working Principle
Wastewater from connected sanitary fixtures enters the sealed PE collection tank through the selected inlet ports.
When the liquid reaches the preset start level, the level-control system sends a signal to the control panel. The pump starts automatically and transfers the collected wastewater through the DN80 discharge line to the main sewer pipe.
The vortex or semi-open impeller generates the required pumping action while allowing permitted solids to pass through the hydraulic section. When the pump stops, the check valve helps prevent reverse flow.
After the level falls to the stop point, the controller shuts down the pump automatically. In a dual-pump system, the controller can alternate the two pumps to distribute operating time more evenly.
The Sewer Lift Pump Residential therefore functions as an integrated collection, level-control, and pressure-discharge system rather than as a stand-alone sewage pump.
Application
This residential sewage lifting system is suitable for:
• Basement bathrooms below the municipal sewer line
• Large villas with multiple toilets or bathrooms
• Residential renovation and extension projects
• Guest bathrooms and household utility rooms
• Small shopping areas and light-commercial premises
• Underground sanitary facilities
• Projects with long horizontal discharge runs
• Locations where reliable gravity drainage cannot be achieved
For kitchen wastewater containing significant grease or oil, we recommend assessing a suitable grease separator and pump arrangement. Grease-rich wastewater should not be treated in the same way as ordinary bathroom sewage.
Contact us to learn more about our products.

Technical Data
| Specification | Details |
|---|---|
| Pumping Medium | Domestic sewage, wastewater from residential buildings, and wastewater from commercial premises |
| Pump Type | Non-clogging sewage pump |
| Impeller Type | Vortex or semi-open impeller, suitable for wastewater containing mixed debris and fibrous materials |
| Rated Power | 1.5–2.2 kW, depending on the selected configuration |
| Pump Body Material | HT250 cast iron or SUS304 stainless steel |
| Impeller Material | HT250 cast iron |
| Shaft Material | SUS410 stainless steel |
| Maximum Solids Passage | 60 mm |
| Outlet Size | DN80 vertical discharge outlet; reducers available for other pipe sizes |
| Control Mode | Dual liquid-level control using air-pressure sensing and a float switch |
| Control Box Protection | IP54 |
| External Power-Control Enclosure | IP68 |
| Motor Protection | Built-in overload and overheat protection |
| Maximum Number of Pump Starts | 120 starts per hour |
| Standard Cable Length | 5 m between the controller and the pump/float switch |
| Check Valve | DN80 check valve included |
| Waterproof Rating | IP68 for the pump and external components, excluding the control box |
| Installation Method | Fixed installation with anchor bolts for anti-floating protection |
Selection note: Final flow, head, and motor power must be confirmed against the actual installation. Please provide the vertical lift, horizontal pipe length, pipe diameter, wastewater type, and expected simultaneous inflow when requesting a quotation.
Products Description
Correct installation directly affects drainage reliability, odor control, operating noise, and maintenance cost. Based on our experience supporting installers and project customers, MISLIER recommends checking the following points.
1. Calculate the Total Head:
Include the vertical lift and pressure losses through horizontal piping, valves, elbows, and fittings. Do not select motor power from vertical height alone.
2. Choose the Correct Inlet Position
Maintain the required drainage slope from each connected fixture. Low-level fixtures such as showers require particular attention to reduce slow drainage and backflow risk.
3. Install the Check Valve Correctly
Fit the supplied DN80 check valve in the correct flow direction. Where required, add an isolation valve so the unit can be serviced without draining the complete discharge line.
4. Provide Proper Ventilation
Connect the collection tank to a correctly sized vent pipe in accordance with local plumbing requirements and route the vent to an appropriate external location. Proper ventilation helps balance pressure and control odor.
5. Secure the Tank
Use the specified anchor points. Anti-floating measures are especially important in areas exposed to flooding or high groundwater levels.
6. Leave Maintenance Access
Do not permanently enclose the unit behind a wall or in a space where the cover, pump, or controls cannot be removed. Allow sufficient room for inspection, cleaning, and replacement.
7. Reduce Pipework Vibration
Flexible connectors, proper pipe supports, and anti-vibration pads can reduce vibration transmitted to the building. Actual noise also depends on the pipe layout, mounting surface, and surrounding room.
8. Test Before Handover
Check inlet seals, the vent connection, check-valve direction, electrical wiring, and control signals. Commission first with clean water and verify automatic start, stop, and alarm functions before admitting sewage.
Electrical installation and commissioning must be completed by qualified personnel in accordance with local regulations.
Why Choose MISLIER
Application-Based Model Selection
We recommend a configuration from the actual drainage layout, wastewater source, fixture quantity, required flow, total head, and available installation space.
Practical Engineering Communication
We explain installation limitations, maintenance access, and unsuitable waste types as well as product parameters, helping distributors and contractors give clearer guidance to end users.
Material Options for Different Projects
HT250 cast-iron and SUS304 stainless-steel pump-body options are available. The final configuration can be discussed against the wastewater characteristics and project specification.
Single- and Dual-Pump Solutions
We support standard single-pump systems and dual-pump arrangements for projects requiring alternating duty or standby capacity.
Standardized Production and Inspection
MISLIER follows defined assembly and inspection procedures. Pump operation, control response, and system sealing can be checked before shipment according to the agreed order requirements.
OEM and Project Support
For distributors, contractors, and private-label customers, we can discuss model configuration, branding, packaging, technical documents, spare parts, and order quantity for the target market.
More external sewage lifting station,Please click on the image below for more information:
|
|
||
| 20 L(Single pump) | 60 L(Single pump) | 120 L(Single pump) |
|
|
|
|
| 150 L(Double pump) | 450 L(Double pump) |
FAQ
Q: How can l choose the right model for the pump?
A: Please let us know the head of the pump and the tlcw ot the pump.l hen we can choose theappropriate pump model and make an offer to you immediately.
Q: How can l pay you?
A: A:T/T, LC,D/P are all available.
Q: How to use the product?
A: After you receive the product, we will guide you to use or pack it with the product manual.
Q: What about the delivery time?
A: Usually the delivery time is about 10~15 days.Iif you need the product badly, we can discussagain to shorten the delivery time and help ycu get the product as soon as possible.
Q: How can l get the best prlce qulckly?
A: Please tell us your name, email address and company name, and then we will send you pricelist immediately.And if you use Whatsapp or Wechat,you can prcvide us your lD, it will be moreconvenient for our communication.
Q: How do I select the correct residential sewer lift pump?
A: Please provide the type and quantity of connected fixtures, required flow, vertical lift, horizontal discharge distance, pipe diameter, power supply, and wastewater type. Our technical team will use these details to recommend a suitable configuration.
Q: Can one unit serve several toilets and bathrooms?
A: Yes. The approximately 150 L tank and multi-inlet arrangement support multi-fixture applications. The expected simultaneous inflow must still be checked against the selected pump capacity and pipe layout.
Q: Can the pump handle wet wipes and sanitary products?
A: No. Wet wipes, sanitary products, cloth, plastic, and other non-dispersible objects may block the impeller or wrap around rotating components.
Q: What is the maximum solids passage?
A: The stated maximum passage is up to 60 mm. This describes the hydraulic passage of the selected pump; it does not mean that every solid object below 60 mm can be pumped safely.
Q: How can odor problems be reduced?
A: Keep the tank correctly sealed and connect the vent according to local plumbing requirements. Regular inspection and cleaning are also important, especially where the property remains unused for long periods.
Q: What information should I send when requesting a quotation?
A: Please send the fixture list, required flow, vertical lift, horizontal distance, discharge pipe diameter, voltage and frequency, wastewater type, installation drawing, and expected order quantity. This helps us prepare a more accurate proposal.
At MISLIER, we work with distributors, installers, and project contractors to review these conditions before confirming a model. If you are selecting a Sewer Lift Pump Residential for a new project, send us the drainage layout, fixture list, vertical lift, and horizontal discharge distance. Our team will help evaluate the appropriate configuration and prepare a project-based quotation.
Hot Tags: sewer lift pump residential, China sewer lift pump residential manufacturers, suppliers, factory, home macerator pump, sewer lift pump station, sewage lift pump station, Macerator Pump









